1.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38610443

RESUMO

The present work proposes a comprehensive metaheuristic methodology for the development of a medical robot for the upper limb rehabilitation, which includes the topological optimization of the device, kinematic models (5 DOF), human-robot interface, control and experimental tests. This methodology applies two cutting-edge triads: (1) the three points of view in engineering design (client, designer and community) and (2) the triad formed by three pillars of Industry 4.0 (autonomous machines and systems, additive manufacturing and simulation of virtual environments). By applying the proposed procedure, a robotic mechanism was obtained with a reduction of more than 40% of its initial weight and a human-robot interface with three modes of operation and a biomechanically viable kinematic model for humans. The digital twin instance and its evaluation through therapeutic routines with and without disturbances was assessed; the average RMSEs obtained were 0.08 rad and 0.11 rad, respectively. The proposed methodology is applicable to any medical robot, providing a versatile and effective solution for optimizing the design and development of healthcare devices. It adopts an innovative and scalable approach to enhance their processes.


Assuntos
Exoesqueleto Energizado , Robótica , Humanos , Comércio , Simulação por Computador , Engenharia
2.
Sensors (Basel) ; 23(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37836903

RESUMO

This article presents an automatic gaze-tracker system to assist in the detection of minimal hepatic encephalopathy by analyzing eye movements with machine learning tools. To record eye movements, we used video-oculography technology and developed automatic feature-extraction software as well as a machine learning algorithm to assist clinicians in the diagnosis. In order to validate the procedure, we selected a sample (n=47) of cirrhotic patients. Approximately half of them were diagnosed with minimal hepatic encephalopathy (MHE), a common neurological impairment in patients with liver disease. By using the actual gold standard, the Psychometric Hepatic Encephalopathy Score battery, PHES, patients were classified into two groups: cirrhotic patients with MHE and those without MHE. Eye movement tests were carried out on all participants. Using classical statistical concepts, we analyzed the significance of 150 eye movement features, and the most relevant (p-values ≤ 0.05) were selected for training machine learning algorithms. To summarize, while the PHES battery is a time-consuming exploration (between 25-40 min per patient), requiring expert training and not amenable to longitudinal analysis, the automatic video oculography is a simple test that takes between 7 and 10 min per patient and has a sensitivity and a specificity of 93%.


Assuntos
Encefalopatia Hepática , Humanos , Encefalopatia Hepática/diagnóstico , Cirrose Hepática , Psicometria/métodos
3.
Enfoque UTE ; 14(3): 36-48, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37521501

RESUMO

Nowadays, the measurement of respiratory dynamics is underrated at clinical setting and in the daily life of a subject and it still represents a challenge from a technical and medical point of view. In this article we propose a concept to measure some of its parameters, such as the respiratory rate (RR), using four inertial sensors. Two different experiments were performed to validate the concept. We analyzed the most suitable placement of each sensor to assess those features and we studied the reliability of the system to measure abnormal parameters of respiration (tachypnea, bradypnea and breath holding). Finally, we measured post-COVID-19 patients, some of them with breath alterations after more than a year of the diagnosis. Experimental results showed that the proposed system could be potentially used to measure the respiratory dynamics at clinical setting. Moreover, while RR can be easily calculated by any sensor, other parameters need to be measured with a sensor in a particular position.


Hoy en día, la medición de la dinámica respiratoria está infravalorada en el ámbito clínico y en la vida diaria de un sujeto y sigue representando un reto desde el punto de vista técnico y médico. En este artículo proponemos un concepto para medir algunos de sus parámetros, como la frecuencia respiratoria (FR), utilizando cuatro sensores inerciales. Se realizaron dos experimentos diferentes para validar el concepto. Analizamos la colocación más adecuada de cada sensor para evaluar esas características y estudiamos la fiabilidad del sistema para medir parámetros anormales de la respiración (taquipnea, bradipnea y retención de la respiración). Por último, realizamos mediciones en pacientes post-COVID-19, algunos de ellos con alteraciones respiratorias después de más de un año del diagnóstico. Los resultados experimentales mostraron que el sistema propuesto podría utilizarse potencialmente para medir la dinámica respiratoria en el ámbito clínico. Además, mientras que la FR puede calcularse fácilmente con cualquier sensor, otros parámetros deben medirse con un sensor en una posición determinada.

4.
Sensors (Basel) ; 22(21)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36365918

RESUMO

Despite the importance of cognitive function in multiple sclerosis, it is poorly represented in the Expanded Disability Status Scale (EDSS), the commonly used clinical measure to assess disability, suggesting that an analysis of eye movement, which is generated by an extensive and well-coordinated functional network that is engaged in cognitive function, could have the potential to extend and complement this more conventional measure. We aimed to measure the eye movement of a case series of MS patients with relapsing−remitting MS to assess their cognitive status using a conventional gaze tracker. A total of 41 relapsing−remitting MS patients and 43 age-matched healthy controls were recruited for this study. Overall, we could not find a clear common pattern in the eye motor abnormalities. Vertical eye movement was more impaired in MS patients than horizontal movement. Increased latencies were found in the prosaccades and reflexive saccades of antisaccade tests. The smooth pursuit was impaired with more corrections (backup and catchup movements, p<0.01). No correlation was found between eye movement variables and EDSS or disease duration. Despite significant alterations in the behavior of the eye movements in MS patients, which are compatible with altered cognitive status, there is no common pattern of these alterations. We interpret this as a consequence of the patchy, heterogeneous distribution of white matter involvement in MS that provokes multiple combinations of impairment at different points in the different networks involved in eye motor control. Further studies are therefore required.


Assuntos
Disfunção Cognitiva , Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Humanos , Movimentos Oculares , Movimentos Sacádicos
5.
Sensors (Basel) ; 22(21)2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36366159

RESUMO

Exploration of the seabed may be complex, and different parameters must be considered for a robotic system to achieve tasks in this environment, such as soil characteristics, seabed gait, and hydrodynamic force in this extreme environment. This paper presents a gait simulation of a quadrupedal robot used on a typical terrigenous sediment seabed, considering the mechanical properties of the type of soil, stiffness, and damping and friction coefficients, referenced with the specialized literature and applied in a computational multibody model with many experimental data in a specific underwater environment to avoi hydrodynamic effects. The requirements of the positions and torque in the robot's active joints are presented in accordance with a 5R mechanism for the leg and the natural pattern shown in the gait of a dog on the ground. These simulation results are helpful for the design of a testbed, with a leg prototype and its respective hardware and software architecture and a subsequent comparison with the real results.


Assuntos
Robótica , Cães , Animais , Fenômenos Biomecânicos , Marcha , Torque , Solo
6.
Sci Rep ; 12(1): 16837, 2022 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-36207472

RESUMO

Minimal hepatic encephalopathy (MHE) is diagnosed using PHES battery, but other tests are more sensitive, and a simple tool for early MHE detection is required. Assessment of saccadic eye movements is useful for early detection of cognitive alterations in different pathologies. We characterized the alterations in saccadic eye movements in MHE patients, its relationship with cognitive alterations and its utility for MHE diagnosis. One-hundred and eighteen cirrhotic patients (86 without and 32 with MHE) and 35 controls performed PHES and Stroop test and an eye movements test battery by OSCANN system: visual saccades, antisaccades, memory-guided saccades, fixation test and smooth pursuit. We analyzed 177 parameters of eye movements, assessed their diagnostic capacity for MHE, and correlated with cognitive alterations. MHE patients showed alterations in 56 of the 177 variables of eye movements compared to NMHE patients. MHE patients showed longer latencies and worse performance in most eye movements tests, which correlated with mental processing speed and attention impairments. The best correlations found were for antisaccades and memory-guided saccades, and some parameters in these tests could be useful for discriminating MHE and NMHE patients. Eye movements analysis could be a new, rapid, reliable, objective, and reproducible tool for early diagnose MHE.


Assuntos
Encefalopatia Hepática , Estudos de Casos e Controles , Movimentos Oculares , Encefalopatia Hepática/patologia , Humanos , Cirrose Hepática/psicologia , Psicometria
7.
Epilepsy Behav ; 123: 108236, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34419714

RESUMO

OBJECTIVE: Oculomotor tasks can be used to measure volitional control of behavior sensitive to frontal dysfunction. This study aimed to examine the saccadic eye movement in Genetic Generalized Epilepsy (GGE) which could correlate with the abnormality of the frontal lobe or the thalamo-frontal network. METHODS: Twenty-one patients with GGE were compared with 22 patients with Temporal Lobe Epilepsy (TLE) and 39 healthy controls. Visual-guided saccades, Antisaccades, and Memory-guided saccades as oculomotor tasks were performed using a novel gaze-tracker designed for clinical practice use. RESULTS: Patients with epilepsy (either GEE or TLE) had similar latency, accuracy, and velocity in visual-guided saccades and memory-guided saccades. Patients with epilepsy had similar latencies and correct antisaccade number. However, healthy volunteers, matched by age, had faster responses and more accurate results than patients with epilepsy. CONCLUSIONS: Our investigations did not reveal differences between TLE and GGE patients' groups in visually guided saccades, antisaccades, and memory-guided saccades, thus suggesting that the frontal cortical mechanisms responsible for them are not explicitly impaired in patients with GGE.


Assuntos
Epilepsia Generalizada , Epilepsia do Lobo Temporal , Epilepsia Generalizada/genética , Epilepsia do Lobo Temporal/complicações , Epilepsia do Lobo Temporal/genética , Movimentos Oculares , Lobo Frontal , Humanos , Movimentos Sacádicos
8.
Sensors (Basel) ; 20(3)2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-32023988

RESUMO

OBJECTIVE: In this article, we present the conceptual development of a robotics platform, called ALICE (Assistive Lower Limb Controlled Exoskeleton), for kinetic and kinematic gait characterization. The ALICE platform includes a robotics wearable exoskeleton and an on-board muscle driven simulator to estimate the user's kinetic parameters. BACKGROUND: Even when the kinematics patterns of the human gait are well studied and reported in the literature, there exists a considerable intra-subject variability in the kinetics of the movements. ALICE aims to be an advanced mechanical sensor that allows us to compute real-time information of both kinetic and kinematic data, opening up a new personalized rehabilitation concept. METHODOLOGY: We developed a full muscle driven simulator in an open source environment and validated it with real gait data obtained from patients diagnosed with multiple sclerosis. After that, we designed, modeled, and controlled a 6 DoF lower limb exoskeleton with inertial measurement units and a position/velocity sensor in each actuator. SIGNIFICANCE: This novel concept aims to become a tool for improving the diagnosis of pathological gait and to design personalized robotics rehabilitation therapies. CONCLUSION: ALICE is the first robotics platform automatically adapted to the kinetic and kinematic gait parameters of each patient.


Assuntos
Exoesqueleto Energizado , Extremidade Inferior/diagnóstico por imagem , Robótica , Dispositivos Eletrônicos Vestíveis , Humanos , Pessoa de Meia-Idade , Fenômenos Fisiológicos Musculoesqueléticos
9.
Front Aging Neurosci ; 12: 603790, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33613262

RESUMO

Oculomotor behavior can provide insight into the integrity of widespread cortical networks, which may contribute to the differential diagnosis between Alzheimer's disease and frontotemporal dementia. Three groups of patients with Alzheimer's disease, behavioral variant of frontotemporal dementia (bvFTD) and semantic variant of primary progressive aphasia (svPPA) and a sample of cognitively unimpaired elders underwent an eye-tracking evaluation. All participants in the discovery sample, including controls, had a biomarker-supported diagnosis. Oculomotor correlates of neuropsychology and brain metabolism evaluated with 18F-FDG PET were explored. Machine-learning classification algorithms were trained for the differentiation between Alzheimer's disease, bvFTD and controls. A total of 93 subjects (33 Alzheimer's disease, 24 bvFTD, seven svPPA, and 29 controls) were included in the study. Alzheimer's disease was the most impaired group in all tests and displayed specific abnormalities in some visually-guided saccade parameters, as pursuit error and horizontal prosaccade latency, which are theoretically closely linked to posterior brain regions. BvFTD patients showed deficits especially in the most cognitively demanding tasks, the antisaccade and memory saccade tests, which require a fine control from frontal lobe regions. SvPPA patients performed similarly to controls in most parameters except for a lower number of correct memory saccades. Pursuit error was significantly correlated with cognitive measures of constructional praxis and executive function and metabolism in right posterior middle temporal gyrus. The classification algorithms yielded an area under the curve of 97.5% for the differentiation of Alzheimer's disease vs. controls, 96.7% for bvFTD vs. controls, and 92.5% for Alzheimer's disease vs. bvFTD. In conclusion, patients with Alzheimer's disease, bvFTD and svPPA exhibit differentiating oculomotor patterns which reflect the characteristic neuroanatomical distribution of pathology of each disease, and therefore its assessment can be useful in their diagnostic work-up. Machine learning approaches can facilitate the applicability of eye-tracking in clinical practice.

10.
Sensors (Basel) ; 18(2)2018 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-29425134

RESUMO

Eye-movement analysis has grown exponentially in recent decades. The reason is that abnormalities in oculomotor movements are usually symptoms of injuries in the nervous system. This paper presents a novel regulated solution named OSCANN. OSCANN aims at providing an innovative tool for the control, management and visualization of oculomotor neurological examinations. This solution utilizes an eye-tracker sensor based on video electro-oculography (VOG) technology to capture eye movements and store them in video files. Such a sensor can store images at a rate of 100 frames per second. A characterization study was performed using twenty-two volunteers (13 male, 9 female, ages 22-45 years, mean 29.3 years, SD = 6.7) to assess the accuracy and precision specifications of OSCANN during oculomotor movement analysis. The accuracy was evaluated based on the offset, whereas precision was estimated with Root Means Square (RMS). Such a study reported values lower than 0.4 ∘ and 0.03 ∘ of accuracy and precision, respectively. These results suggest that OSCANN can be considered as a powerful tool to measure oculomotor movement alterations involved in some neurological disease progression.


Assuntos
Fixação Ocular , Adulto , Eletroculografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Gravação em Vídeo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...